USER NOTE: This serves as additional information for Pulsafeeder PULSAR® and PULSAR Shadow® metering pumps
equipped with the Automatic Valve Assembly for purging trapped gasses from the reagent head. You must also reference
the latest revision of the complete PULSAR® or PULSAR Shadow® pump IOM for critical safety and operational
information.
PULSAR
®
HYPOPUMP
®
SODIUM HYPOCHLORITE
METERING PUMP
Bulletin #: PS-IOM-HYP-0203-I
Installation, Operation &
Maintenance Instruction
Vedere la pagina 0
1 2 3 4 5 6 ... 14 15

Sommario

Pagina 1 - Maintenance Instruction

USER NOTE: This serves as additional information for Pulsafeeder PULSAR® and PULSAR Shadow® metering pumps

Pagina 2 - Revision History:

6 7. Description and Operation 7.1 Principle of Operation Reciprocating metering pumps are used with a wide variety of chemicals, such as sodium hy

Pagina 3 - Table of Contents

7 8. Maintenance NOTE: This section only refers to models purchased and installed prior to [date] and is for reference only. Replacement parts are n

Pagina 4 - 1. Conventions

8 8.2 Flapper Valve Replacement 1. Remove automatic valve assembly completely from pump, as per the instructions in the previous section. 2. Remove

Pagina 5 - 2. General Safety

9 9. Troubleshooting Guide Symptom Probable Cause Possible Solution Pump does not prime (product side) Purge relay not operational Verify power is

Pagina 6 - 4. Storage

10 10. Wiring Diagrams Figure 7 It is recommended that the AVA be powered from a Ground Fault Circuit Interrupter (GFCI) protected electrical circui

Pagina 7 - 5. Overall System Diagram

11 PULSAR® HYPOPUMP® SODIUM HYPOCHOLORITE METERING PUMP Bulletin #: PS-IOM-HYP-0203-I A unit of IDE

Pagina 8 - 6. Installation

ii FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting guide.

Pagina 9 - 6.3 Electrical Wiring

iii Table of Contents 1. CONVENTIONS ...

Pagina 10 - 7.2 General Description

iv 1. Conventions For the remainder of this bulletin, the following Conventions are in effect. A WARNING DEFINES A CONDITION THAT COULD CAUSE DAMA

Pagina 11 - 8. Maintenance

1 2. General Safety The Automatic Valve Assembly (AVA) was designed as a gas handling/priming aid for operation solely with Pulsafeeder PULSAR® and

Pagina 12

2 3. Equipment Inspection When you receive your order, check all equipment for:  Completeness against the shipping document / purchase order  Evi

Pagina 13 - 9. Troubleshooting Guide

3 5. Overall System Diagram Figure 1PULSAR® HypoPump® System Diagram

Pagina 14 - 10. Wiring Diagrams

4 6. Installation 6.1 Location Review the Safety section prior to installing the pump with AVA. It contains information required to properly insta

Pagina 15 - HYPOPUMP

5 AVOID LOCATIONS WHERE THE AVA WOULD BE SUBJECTED TO EXTREME COLD OR HEAT OR DIRECT SUNLIGHT. FAILURE TO OBSERVE THIS WARNING COULD DAMAGE THE AVA

Commenti su questo manuale

Nessun commento